Return to Layfield Group homepage


SAMPLE REINFORCED 3PLY* HYPALON®(CSPER) GEOMEMBRANE LINER
PHYSICAL DATA SPECIFICATIONS

*1 PLY REINFORCING 10X10 1000 DENIER SCRIM

NOTE: OTHER PLY CONFIGURATIONS ARE AVAILABLE UPON REQUEST.

.036" (36 MIL), .045" (45 MIL) AND .060" (60 MIL)

 

Property

Test Method

Minimum Values

Thickness

1. Total, overall (mils)

ASTM D751

34

41

55

2. Min. over scrim (mils)

Optical Method

11

11

11

Tensile Properties

ASTM D751

(each direction)

Grab Method

1. Breaking Strength (lbs.) Fabric

200

200

270

Membrane Rupture

150

150

175

2. Elongation at Break Fabric

15%

15%

15%

Membrane Rupture

30%

30%

30%

Tear Propagation (lbs.)

ASTM D751

80

80

90

Hydrostatic Resistance (psi.)

Tongue Tear (8"x8"sample)

250

250

300

Puncture Resistance (lbs.)

FTMS 101B Method 2031

-

-

-

Bonded Seam Strength (lbs.)

ASTM D751

160

160

205

Ply Adhesion (lbs./in. width)

ASTM D413 Machine Method, Type A (12in./min.)

7 (or film tearing bond)

7 (or film tearing bond)

7 (or film tearing bond)

Ozone Resistance

ASTM D1149, 1/8" bent loop, 100pphm, 104°F, 7days

No cracks at 7X magnification

No cracks at 7X magnification

No cracks at 7X magnification

Low Temperature

ASTM D2136, 1/8" mandrel, 4 hrs. @ -40°F

pass

pass

pass

 