Return to Layfield Group homepage


SAMPLE REINFORCED COOLGUARD™ HR (TRIPOLYMER ALLOY/ELVALOY®)
GEOMEMBRANE LINER PHYSICAL DATA SPECIFICATIONS

 

.036" (36 MIL) & .045" (45 MIL)

PROPERTY

TEST METHOD

VALUE

Gauge, Nominal (Mils)

ASTM-D751

36±10%

45±10%

Plies Reinforcing

6.5 Ounce

1

1

Tongue Tear

ASTM-D751

135 x 135 lbs.

135 x 135 lbs.

(LBS Min.)

Procedure B

Trapezoid Tear

ASTM-D1117

75 x 75 lbs.

75 x 75 lbs.

(LBS Min.)

Section 14

Grab Tensile

ASTM-D751

500 x 450 lbs.

500 x 450 lbs.

(LBS Min.)

Procedure A

Strip Tensile

ASTM-D751

400 x 300 lbs.

400 x 300 lbs.

(LBS Min.)

Procedure B

Ply Adhesion

ASTM-D751

10 lbs.

10 lbs.

(LBS Min.)

Hydrostatic Resistance

ASTM-D751

600 psi

600 psi

(P.S.I. Min)

Procedure A

Puncture Resistance

ASTM-D751

600 lbs.

600 lbs.

(1" Ball)

Low Temperature

ASTM-D2136

-30°F

-30°F

(Deg. F)

Dimensional Stability

ASTM-D1204

2% Max.

2% Max.

(% Max)

(1 Hr. @ 212°F)



Home Geomembrane Containment Floating Cover Systems Erosion & Sediment Control Tarps & Enclosures Packaging Products